N045--Boiler 3 Oxygen Analyzer and Steam Flow Meter

Due: 3 days leftSolicitationSDVOSBCGA
What: Supply and install oxygen analyzer and steam flow meter for Boiler 3. Oxygen analyzer must send control signals to burner combustion controls. Steam flow meter outputs 4-20 mA analog signal to local CB Hawk control terminal. Stack is double-wall steel/galvanized (36" Selkirk Metalbestos Model P.S.). System design: 200 psi pressure, 82 psi typical operating, 330°F typical temperature. Buyer: Department of Veterans Affairs Where: Dublin, Georgia Deadline: October 26, 2026 Who can bid: Only Service-Disabled Veteran-Owned Small Businesses certified by SBA VetCert program are eligible. Key requirements: Not stated in the notice summary Check before bidding: (1) Full technical specifications and statement of work in attachments; (2) Installation timeline and site visit requirements Next step: Obtain complete solicitation attachments and submit bid/quote by October 26, 2026 at 3:00 PM UTC.
Buyer
VETERANS AFFAIRS, DEPARTMENT OF
Place of performance
Dublin, GA, 31021
Response deadline
Monday, October 26, 2026 at 11:00 AM ET
NAICS code
238220
Contracting contact
Sheryl Harris · sheryl.harris5@va.gov

Original description

Questions and Answers 36C24727Q0050 Boiler #3 Oxygen Analyzer and Steam Flow Meter RFI Responses Where should the output signals from the new steam flow meter and O2 analyzer terminate? For example, the existing building automation system (BAS), the existing Boiler 3 burner/boiler controls, or a local display only. Burner 3 boiler/burner controls where applicable and local display. Does the government require active O2 trim control to the burner fuel/air ratio, or monitoring and display of the O2 only? Oxygen analyzer must send signals/information to combustion controls to control trim. What is the material of construction for the stack? Is it single or double wall? Stack is double walled. Inside material is steel; outside material is galvanized steel. Stack is 36 D Selkirk Metalbestos Model P.S. Current operating pressure and temperature of the system for boiler #3? Design pressure is 200 psi. Typical operating pressure is 82 psi. Typical operating temperature is about 330 degrees Fahrenheit. What are the available outputs on the physical steam flow meter (e.g., 4-20 mA, Modbus RTU, BACnet MS/TP)? 4-20 mA analog. Is the flow meter wired directly into an analog terminal block on the CB Hawk, or is it wired directly to the facility s Building Automation System (BMS)? Steam flow meter is wired into local CB Hawk analog terminal block. Please provide nameplates for the existing oxygen analyzer and steam flow meter. Oxygen analyzer nameplate: Steam flow meter nameplate: